Solar & Smart Energy Pre-Planning

Enter your appliances. Get the system size, the roof area to keep shadow-free, and the conduits and earthing to build in now.

← All tools

Inverter AC (1.5 ton)
Fans
Lights (LED)
Refrigerator & water pump
Installation

Recommended solar system

10 kW

18 panels × 580 W = 10.44 kWp · hybrid/on-grid inverter 10 kW (3-phase) · ≈ 1,175 units/month

Daily use

26.8 kWh

Peak load

4.9 kW

Needed

7.1 kW

Shadow-free roof area

897 sq ft

Tilted array on a flat RCC roof (rows spaced to avoid self-shading). Flush-mounted on a sloped roof: 573 sq ft.

Battery backup

Grid-tied with net metering (no battery). Enter backup hours to size a battery for essential loads.

Embed before plastering: conduits, cables & earthing

DC cable (roof → inverter), per string
4 mm² PV1-F (UV, double-insulated) · 0.6 % drop
DC conduits
2 × 1 in (25 mm) heavy-gauge PVC (≈ 2 strings + 1 spare)
AC cable (inverter → DB)
4 mm² Cu · 15 A 3Φ · 1 in (25 mm)
Main DB disconnect (AC MCB)
20 A 4P + 30 mA RCD
DC isolator
1000 V DC, ≥ 25 A
Surge protection
Type-2 SPD on DC and AC sides
Earthing rods
3 pits: array · AC/inverter · lightning, each 8–10 ft deep
Earth conductors
Array 6 mm² · inverter 10 mm² · lightning 16 mm² bare Cu
  • Run the conduits in the wall/column chase from the roof to the inverter wall (near the main DB, shaded, ventilated, ≥ 4 ft high). Use sweeping bends and leave a pull-rope.
  • Bury earth rods (≥ 10 ft apart) before the compound floor is cast; keep an inspection pit cover on each.
  • Roof: build a 1 ft-high RCC plinth with anchor bolts or leave a clear 4 in cut-out for each leg, then waterproof around it.
  • Net metering: apply through your DISCO (e.g. PESCO) with the installer; the approved layout may differ.
Roof plan (view from above)North parapet / mumty shadow – keep clear(panels ≥ 3× obstacle height away)Tank18 panels × 580 W (showing 18)NPanels face SOUTH ↓DC conduit chase (roof → inverter wall)Side view: tilt & row gap≈ 30°gap ≈ 3–4 ftSun (south)Tilt ≈ Haripur latitude (34°) minus a few degrees → 28–30°.Embedded before plasteringDC conduit (PV1-F)AC conduit → DBEarth rod: 8–10 ft deep × 3 pits (array · AC · lightning),≥ 10 ft apart, bonded together, ≤ 5 Ω; charcoal/salt/bentonite fill.

Assumptions: 5 peak-sun-hours/day (Haripur average), 75 % system efficiency, 1.5-ton inverter AC ≈ 1,100 W average, fridge ≈ 2 kWh/day. This is a pre-planning estimate; the installer's design governs.

Advisory only

This guide is general advice for Haripur / Hazara homeowners. It does not replace a site-specific design by a registered structural engineer (PEC), a soil test, or legal advice from a lawyer. Always follow the approved drawings.